Home > New >

Eaton 3 kVA 9PX On Line Rack/Tower UPS 120V, New Open Box

 
Alternative Views:


List Price: $3,650.00
Our Price: $1,499.99
You save $2,150.01!

Availability:: Usually Ships in 2 to 3 Business Days
Product Code: 9PX3000RT
Qty:

Description
 
General
TopologyDouble-conversion online
ConfigurationRack/Tower
Catalog Number9PX3000RT
ColorBlack and silver
Rating (VA/Watts)3000/2700

DiagnosticsFull system self test at power up, and ABM test every 30 days
UPS BypassEHBPL3000R-PDU1U optional
Dimensions (H x W x D, inches)3.4 (2U) x 17.3 x 23.8
Dimensions (H x W x D, mm)86.5 x 440 x 605
Weight (kg)28.6
Weight (lbs)63.1
Warranty2 years
Rail Kit Included4-post rail kit and tower pedestals included
Remote Emergency Power off (REPO)ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off)
Contents
(Ships with the following items)
9PX3000RT 3 kVA UPS
4-post rail kit
Safety manual
User manual
Tower pedestals
RS-232 serial cable
USB cable
Intelligent Power Software Suite CD
Efficiency91% with resistive load

Electrical Input
Connection
(1) NEMA L5-30P
L5-30P
Input Cord8 feet
Input Voltage RangeFull load: 100-144V, <30% load: 60-144V
Nominal Voltage120V default (100/110/120/125V)
Frequency50/60 Hz
Frequency Range60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz
Input Power Factor>.99
Input Current Distortion<5%

Electrical Output
Nominal Voltage120V default (100/110/120/125V)
Output voltage regulation±1% steady-state
Voltage THD<3% for linear loads
Output Receptacles
(6) NEMA 5-20R
5-20R
(1) NEMA L5-30R
L5-30R
Transfer Time0 ms
Circuit Breaker
(2) 20A for 5-20R
Optional Extended Battery Module9PXEBM72RT
Battery DescriptionSealed, lead-acid; maintenance free
Maximum number of extended battery modules (EBM)Add up to 4 extended battery modules (EBM)
Battery ManagementABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement
Battery ReplacementReplaceable internal batteries and extended battery modules (EBMs)
Start On BatteryCold-start enabled; first cold start is always forbidden

Communications
User InterfaceGraphical display. UPS status in a single view.
LEDs4 status-indicating LEDs
Communication PortsRS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Power Management SoftwareEaton Intelligent Power Manager

Environmental & Standards
RoHS ComplianceYes
Surge ProtectionIEEE ANSI C62.41 Cat B2
Heat Dissipation (BTU)Online: 844
Battery: 1462
(BTU/hr; battery full charged, resistive load)
Audible Noise≤47 dB at 1 meter
Operating Temperature0 to 40°C (32°F to 104°F)
Safety markingsCE / cULus / NOM
EMC MarkingsIEC 62040-2 Cat C1 / CISPR22 / FCC part 15 Class B / VCCI Class B
Storage Temperature0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F)
Relative Humidity0 to 96% non-condensing
Altitude3000m


Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

New
Tower UPS LV
Tower UPS LV > OnLine
Tower UPS LV > OnLine > 2001VA to 3000VA
Rackmount UPS LV
Rackmount UPS LV > RM OnLine
Rackmount UPS LV > RM OnLine > 2001VA to 3000VA