Home > New >

Eaton 5 kVA 9PX On Line Rack/Tower UPS 208-230V

 
Alternative Views:


List Price: $5,592.00
Our Price: $2,900.00
You save $2,692.00!

Availability:: Usually Ships in 2 to 3 Business Days
Product Code: 9PX5K
Qty:

Description
 
9PX5K Technical Specifications
Topology Double-conversion online
Configuration Rack/Tower
Catalog Number 9PX5K
Color Black and silver
Rating (VA/Watts) 5000/4500
Diagnostics Full system self test at power up
UPS Bypass MBP6K208 optional
Dimensions (H x W x D, inches) 5.1 (3U) x 17.3 x 28.4
Dimensions (H x W x D, mm) 130 (3U) x 439 x 721
Weight (kg) 48
Weight (lbs) 110
Warranty 2 years
Rail Kit Included 4-post rail kit and tower pedastals included
Remote Emergency Power off (REPO) ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off)
Contents
(Ships with the following items)
9PX5K 5 kVA UPS
Network-MS Web/SNMP card
4-post rail kit
User manual
Quick start guide
Tower pedestals
Intelligent Power Software Suite CD
RS-232 serial cable
USB cable
Cable gland for hardwire connection
Phillips head screw driver
Efficiency 93% with resistive load
Electrical Input
Connection
(1) Terminal block with L6-30P
L6-30P
Input Cord 6 feet (1.8 meters)
Input Voltage Range Full load: 176-276V, Derating: 100-276V
Nominal Voltage 208V default (200/208/220/230/240V)
Frequency 50/60 Hz
Frequency Range 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz
Input Power Factor >99
Input Current Distortion <5%
Electrical Output
Nominal Voltage 208V default (200/208/220/230/240V)
Output voltage regulation ±1% steady-state
Voltage THD <2% for linear loads
Output Receptacles
(2) NEMA L6-20R
L6-20R
(2) NEMA L6-30R
L6-30R
Hardwired - see manual for terminal block layout
Hardwired - example layout only
Power Factor 0.9
Transfer Time 0 ms
Circuit Breaker (2) 20A for L6-20R

Optional Extended Battery Module 9PXEBM180RT
Battery Description Sealed, lead-acid; maintenance free
Maximum number of extended battery modules (EBM) Add up to 4 extended battery modules (EBM)
Battery Management ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement
Battery Replacement Hot-swappable internal batteries and extended battery modules (EBMs)
Start On Battery Cold-start enabled; first cold start is always forbidden
Communications
User Interface Graphical display. UPS status in a single view.
LEDs 4 status-indicating LEDs
Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Communications Card Slots Network Card-MS included
Power Management Software Eaton Intelligent Power Software Suite CD (included)
Environmental & Standards
RoHS Compliance Yes
Surge Protection IEEE ANSI C62.41 Cat B2
Heat Dissipation (BTU) Online: 1150
Battery: 1560
(BTU/hr; battery full charged, resistive load)
Audible Noise <45 dB at 1 meter
Operating Temperature 0 to 40°C (32°F to 104°F)
Safety markings CE / cULus / NOM
EMC Markings IEC 62040-2:2006 Cat C2 / CISPR22 Class A / FCC part 15 Class A
Storage Temperature 0 to 35°C (32°F to 95°F); without batteries: -15 to 60°C (5°F to 140°F)
Relative Humidity 0 to 95%
Altitude <1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters)

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

New
Rackmount UPS HV
Rackmount UPS HV > RM On-Line
Rackmount UPS HV > RM On-Line > 3001VA to 7000VA
Tower UPS HV
Tower UPS HV > On-Line
Tower UPS HV > On-Line > 3001VA to 7000VA